RTI uses cookies to offer you the best experience online. By clicking “accept” on this website, you opt in and you agree to the use of cookies. If you would like to know more about how RTI uses cookies and how to manage them please view our Privacy Policy here. You can “opt out” or change your mind by visiting: http://optout.aboutads.info/. Click “accept” to agree.
Development and preclinical evaluation of a dual-drug implant for long-acting HIV prevention and contraception
Krovi, A., Levin, L., Gatto, G. J., Luecke, E. H., Brand, R., Swistok, A., Cottrell, M. L., Schauer, A. P., & Johnson, L. M. (2026). Development and preclinical evaluation of a dual-drug implant for long-acting HIV prevention and contraception. Pharmaceutics, 18(9), Article 1060. https://doi.org/10.3390/pharmaceutics18091060
Background/Objectives: Multipurpose prevention technologies (MPTs) that combine protection against HIV and unintended pregnancy can improve women's health outcomes by simplifying use and enhancing adherence. We developed a long-acting (LA) implant for the simultaneous and sustained delivery of the antiretroviral islatravir (ISL) and the contraceptive hormone etonogestrel (ENG). Methods: Using extruded poly-ε-caprolactone (PCL) tubing, reservoir-style implants were fabricated and evaluated in three configurations: (Group 1) a two-segment implant formed by joining separate ISL- and ENG-containing tubes; (Group 2) a single tube divided into two drug compartments by a heat-sealed PCL spacer; (Group 3) separate single-drug implants. In vitro release was assessed in phosphate-buffered saline at 37 °C, and safety and pharmacokinetic (PK) profiles were evaluated in New Zealand White rabbits (n = 4/group) over approximately 90 days. Results: The average ISL daily in vitro release rates for Groups 1, 2, and 3 were 29 ± 5 µg/day, 18 ± 5 µg/day, and 47 ± 8 µg/day, respectively, and ENG daily in vitro release rates were 39 ± 9 µg/day, 41 ± 8 µg/day, and 33 ± 7 µg/day. From day 28 through the end of the study, median (IQR) plasma concentrations were 0.22 (0.18-0.27) ng/mL, 0.28 (0.24-0.33) ng/mL, and 0.31 (0.28-0.33) ng/mL for ISL in Groups 1, 2, and 3, respectively, and 0.26 (0.21-0.31) ng/mL, 0.25 (0.16-0.47) ng/mL, and 0.30 (0.23-0.38) ng/mL for ENG in Groups 1, 2 and 3, respectively. Implants across all groups were well tolerated and demonstrated favorable local tolerability over the 90-day dosing period. Conclusions: Integration of multiple indications into a single platform capable of sustained release over an extended duration holds potential to address persistent gaps in women's sexual and reproductive health needs.
RTI shares its evidence-based research - through peer-reviewed publications and media - to ensure that it is accessible for others to build on, in line with our mission and scientific standards.